Calibration Certificate – Certification Service in Bangladesh

Calibration certification refers to the process of verifying that a measuring instrument or device, such as a thermometer or scale, is accurate and conforms to a set of standards. This process is often performed by a third-party calibration laboratory and can include testing and adjusting the device as necessary. Once the device has been calibrated, it may be issued a calibration certificate indicating that it meets the relevant standards and can be used with confidence for measurement and data collection. It is important to note that calibration needs to be done periodically to ensure the device continues to function within the required specifications.

What is Calibration Certificate

A Calibration Certificate is a document that certifies that a device or instrument has been calibrated and found to perform within specified limits. The certificate provides evidence that the device or instrument has been tested and verified against standards of measurement traceable to national or international standards organizations. The certificate includes information about the device or instrument, including its type, model, serial number, range, and accuracy. It also includes information about the standards used in the calibration, the date of calibration, and the name of the organization or individual who performed the calibration. Calibration Reports are important for maintaining quality control, ensuring the accuracy and reliability of measurements, and for compliance with regulatory requirements in various industries.

Importance of calibration certification

Calibration certification is important because it ensures that measuring instruments and equipment are accurate and reliable. This is critical for many industries, such as manufacturing, healthcare, and scientific research, where precise measurements are essential for quality control and compliance with regulations. Calibration certification also helps to identify and correct any errors in measurement, which can lead to improved efficiency and cost savings. Additionally, calibration certification can be a requirement for many organizations to meet industry standards and regulations. Read more about Calibration Certificates for Laboratory Equipment.

Our Certificate

Calibration Certification standards

Calibration is the process of determining the deviation of a measurement instrument or system from a standard and adjusting it accordingly. Calibration certification is a process by which an independent third-party organization verifies that a company’s measurement instruments or systems meet certain standards and specifications. There are a number of different calibration certification standards, including ISO/IEC 17025 and ANSI/NCSL Z540-1.

ISO/IEC 17025 is an international standard that specifies the general requirements for the competence of testing and calibration laboratories. It covers management, technical, and infrastructure requirements, and is widely recognized as the global benchmark for laboratory quality and competence.

ANSI/NCSL Z540-1 is a standard developed by the National Conference of Standards Laboratories that provides guidelines for the calibration and repair of measurement and test equipment. It is widely used in the United States, and is often required by government agencies and other organizations that need to ensure the accuracy and traceability of their measurements.

Both of these standards cover the same basic requirement, but ANSI/NCSL Z540-1 is more specific to the USA and is used by the US federal agencies and other organizations that need to ensure the accuracy and traceability of their measurements.

In summary, Calibration Certification standards are a set of requirements that ensure that a company’s measurement instruments or systems meet certain standards and specifications, making sure that their measurements are accurate and reliable.

Accredited Calibration Certificate Requirements

A calibration certificate is a document that verifies that a measuring instrument has been tested and found to meet specified standards. The requirements for a certificate depend on the specific industry or application, but generally, the certificate should include the following information:

  1. Identification of the instrument: The certificate should clearly identify the instrument that has been calibrated, including the manufacturer, model number, serial number, and any other relevant details.
  2. Calibration date: The date on which the instrument was calibrated should be included.
  3. Calibration procedure: The certificate should describe the calibration procedure that was used, including the standards and equipment used for the calibration.
  4. Measurement results: The certificate should include the measurement results obtained during the calibration, including any deviation from the specified standards.
  5. Uncertainty of measurement: The certificate should include an estimate of the uncertainty of measurement, which is a measure of the confidence that can be placed in the measurement results.
  6. Signature and accreditation: The certificate should be signed by the person who performed the calibration, and the laboratory or organization that performed the calibration should be accredited by a recognized accreditation body.
  7. Traceability: The certificate should demonstrate traceability to national or international standards, meaning that the standards used for calibration can be traced back to a recognized source, such as a national metrology institute.
Click Calibration Certificate Requirements to read more about certification prerequisite in details.

Correction Factor in Calibration Certificate?

A correction factor is a value that is used to adjust the readings of a device or instrument to compensate for any systematic errors or inaccuracies. The correction factor is typically applied during the calibration process and is recorded on the Calibration Certificate as a part of the results of the calibration. The correction factor can be either a constant value or a function that depends on the specific conditions of the measurement.

In the case of a constant correction factor, it is usually applied as an offset to the readings of the device or instrument. For example, if the correction factor is 0.5, then 0.5 would be subtracted from each measurement reading to correct for the systematic error.

In the case of a correction factor that depends on the measurement conditions, it may be recorded on the Calibration document as a table or graph, showing the relationship between the correction factor and the specific conditions under which the measurement is made. In such cases, the correction factor is used to correct for non-linear errors or to account for changes in the measurement environment that affect the accuracy of the device or instrument.

The use of correction factors in the calibration process helps to improve the accuracy and reliability of the device or instrument, ensuring that it performs within specified limits and meets the requirements of quality control and regulatory compliance. Calibration certificates that include correction factors provide a record of the performance of the device or instrument, allowing users to make informed decisions about the use of the device and to verify that it continues to perform within specified limits over time.

Calibration certificate in Bangladesh: challenges and solutions

A calibration certificate in Bangladesh is a document that certifies that a specific measuring instrument has been calibrated and found to be in compliance with national or international standards. Some of the challenges faced in obtaining an aaccredited calibration certificate in Bangladesh include a lack of proper infrastructure and trained personnel, as well as a lack of standardization and regulation. Potential solutions to these challenges include investing in training programs for personnel, implementing and enforcing regulations, and investing in the development of infrastructure. Additionally, promoting the use of international standards and encouraging collaboration between industry and government entities can also help to improve the calibration certification process in Bangladesh.

On-Site calibration Certification services 

On-site calibration certification services involve technicians visiting a customer’s location to calibrate and certify equipment. This can include measuring and adjusting devices such as scales, pressure gauges, and temperature sensors to ensure they are operating within their specified tolerances. On-site calibration can be beneficial for companies as it allows them to keep their equipment in use while it is being calibrated, minimizing downtime and potential loss of productivity. Additionally, on-site calibration ensures that equipment is calibrated in its actual working environment, providing more accurate results.

Calibration certification for medical devices

Calibration certification for medical devices is a process that ensures that the device is accurate and reliable in measuring the intended parameter. This is typically done by a third-party calibration laboratory that compares the device’s measurements to those of a known standard. The laboratory then issues a certificate indicating the device’s calibration status and any adjustments that were made. Calibration certification is important for ensuring patient safety and the accuracy of medical diagnoses and treatments. Some regulatory agencies, such as the US Food and Drug Administration (FDA), require calibration certification for certain types of medical devices.

Traceability and Accreditation in calibration certificate

Traceability in calibration refers to the ability to trace the measurements made by a particular instrument or system back to a known standard. Accreditation in calibration certification refers to the process of evaluating and certifying the competence of a calibration service provider to perform specific types of calibrations. Accreditation bodies, such as the National Institute of Standards and Technology (NIST) in the US, assess the laboratory’s technical competence and ensure that the laboratory is following internationally recognized standards. This provides assurance that the calibration services provided by an accredited laboratory are accurate and reliable.

Maintaining calibration records in certification

Maintaining calibration records is an important aspect of certification. Calibration refers to the process of adjusting and testing equipment to ensure that it is accurate and reliable. Keeping detailed records of calibration procedures, including the equipment used, the results obtained, and the dates of calibration, can help demonstrate compliance with relevant regulations and standards, as well as provide a history of the equipment’s performance over time. Additionally, it can be used for troubleshooting and maintenance purposes.

The role of quality control in calibration certification

Quality control plays a crucial role in the calibration certification process. It ensures that the equipment used for calibration is accurate and reliable, and that the calibration process itself is performed correctly. This includes regular checks of the equipment to ensure that it is functioning within specified tolerances, as well as audits of the calibration process to ensure that it is being conducted in accordance with established procedures and standards. Additionally, quality control measures help to identify and correct any issues that may arise during the calibration process, which helps to ensure the accuracy and reliability of the final calibration certification.

GMP and GLP compliance in calibration certification

GMP (Good Manufacturing Practices) and GLP (Good Laboratory Practices) are regulatory standards that ensure the quality and consistency of products and processes in the pharmaceutical and biotech industries. GMP compliance is required for manufacturers of drugs and medical devices, while GLP compliance is required for laboratories conducting non-clinical studies.

Calibration certification is a process that involves testing and verifying the accuracy of measuring instruments, such as scales and pH meters, to ensure that they are performing within established tolerance levels. Both GMP and GLP compliance require that calibration be performed on a regular basis and that proper documentation be kept to demonstrate that the instruments are accurate and reliable.

In GMP regulated facilities, the calibration certification process must be in compliance with the guidelines for equipment maintenance and calibration outlined by regulatory agencies such as the FDA. In GLP regulated facilities, the calibration certification process must be in compliance with the guidelines for laboratory equipment maintenance and calibration outlined by regulatory agencies such as the FDA.

It’s important to note that GMP and GLP compliance are not only required for calibration certification but also for all other aspects of manufacturing and laboratory operations, including production, quality control, and record keeping.

Advancement in calibration Certification techniques

There have been several advancements in calibration certification techniques in recent years. Some examples include:

  • Uncertainty analysis: There are now more advanced methods for determining the uncertainty associated with a measurement, which improves the accuracy of calibration certificates.
  • Traceability: The use of international standards and metrological traceability has become more widespread, ensuring that measurements are comparable across different laboratories and countries.
  • Automation: There has been an increased use of automated systems for calibration and measurement, which improves the efficiency and consistency of the process.
  • Remote Calibration: There has been an Increase in Remote Calibration , which allows for calibration of instruments located at remote locations, this is done through internet and remote access.
  • Mobile Calibration: There has been an increase in the development of mobile calibration systems, which allow for on-site calibration of instruments, this can improve efficiency and reduce downtime.

Difference between a Standard Traceable and Accredited Calibration Certificate?

A “traceable calibration certificate” and an “accredited calibration certificate” have distinct differences:

Traceable Calibration Certificate:

  1. Traceability: A traceable calibration certificate provides evidence that the calibration measurements were referenced to a known, documented, and internationally recognized measurement standard.
  2. Calibration Process: The calibration is performed by a calibration laboratory or service provider that ensures the accuracy of the measurements and maintains traceability to established standards.
  3. Documentation: The certificate includes information about the equipment calibrated, the calibration procedure followed, the calibration results, and a statement indicating the traceability to the relevant standard.
  4. Verification: The traceability of the measurements is verified through a documented chain of comparisons, demonstrating a clear link to the original standard.

Accredited Calibration Certificate:

  1. Accreditation: An accredited calibration certificate is issued by a calibration laboratory that has been assessed and accredited by a recognized accrediting body, such as ISO/IEC 17025.
  2. Compliance with Standards: Accredited calibration laboratories must demonstrate competency, proficiency, and compliance with specific technical and quality management requirements outlined by the accrediting body.
  3. Independent Evaluation: The laboratory undergoes regular assessments and audits to ensure ongoing adherence to the accreditation standards.
  4. Authority and Recognition: An accredited calibration certificate holds higher credibility and acceptance in regulatory, industry, and international contexts due to the rigorous evaluation and oversight processes associated with accreditation.

In summary, a traceable calibration certificate indicates that the measurements are referenced to a known standard, while an accredited calibration certificate signifies that the calibration laboratory itself has been evaluated and accredited for its technical competence and compliance with recognized standards. Accreditation adds an additional layer of assurance and credibility to the calibration process

Future of calibration certificate in Bangladesh

It is difficult to predict the specific future of calibration certification in Bangladesh as it may depend on various factors such as government regulations and industry demand. However, it is likely that there will be an increasing need for calibrated equipment and measurement devices in various industries, such as manufacturing, construction, and telecommunications, as the country continues to develop and modernize. This may lead to an increased demand for calibration services and certified professionals. Additionally, the Bangladesh government may also implement or update regulations related to calibration and measurement to ensure quality and accuracy in various industries.

If you’re looking for a 17025 BAB Accredited Calibration Company in Bangladesh Quality Calibration Solutions is here to help, equipped with well trained and experienced Engineers to meet your requirements.

Other Calibration Certificates we Provide

We understand the importance of approaching each work integrally and believe in the power of simple.

Melbourne, Australia
(Sat - Thursday)
(10am - 05 pm)